![]() System can be mounted to pipe or wall with optional wall bracket that is provided. Switch will activate at 2.4 gpm (9.08 L). Unit is activated when the emergency shower or eyewash is in operation. If you have been informed that an extinguisher has been used/damaged or it does not pass the test shown above, contact your maintenance contractor immediately.Model 9001ExP Class 1, Division 2, Groups B, C and D emergency alarm and light system features a red flashing light and 90 db at 10 feet (304.8 cm), buzzer that is operated by a double pole, double throw flow switch. Please ensure you lift the extinguisher using the correct lifting and handling method as extinguishers can be heavy !!.Fill in your logbook (downloadable NFASS log sheet available on this page).Ensure the usage sign is fitted by the extinguisher.Ensure the wall hook is secure and not damaged.Check the instructions on the extinguisher can be clearly read.Visually inspect the extinguisher (including the handle and hose) for dents or damage.Check the gauge (if fitted) is within the green.Check the anti-tamper pin is present (a metal or plastic pin that goes through the handle).Check the plastic anti-tamper seal is in one piece (a plastic tag usually through the pin).This test is very simple and does not take long to undertake: ![]() Most of our customers undertake this check at the same time as their emergency lighting checks. To prevent contravening the British Standards 5306, your extinguishers should be visually inspected by a competent person once every month. Turn the key to position or press Reset.If this is the third false alarm within a short period of time contact your Fire Alarm maintenance company.Make a note of the zone and the device location that caused the alarm.If this is the second false alarm and you can confidently and safely reach the smoke detector……Hoover the head by cupping your hand round the back of the detector Hoovering the front……then rotate your hoover and hand to Hoover 360 degrees.After discovering the device that caused the activation and you believe without any doubt this was a false alarm……return to the panel.….You are looking for a LED (small red light) illuminated on a ceiling detector or a smashed call point (break glass). If safe to do so: Investigate the area shown on the panel.Remove key or allow code to expire (to prevent unwanted other user intervention).Turn the key to position or press Silence.Type in the code or turn the test key at the panel.We have found this is a more cost-effective way to eliminate unwanted false alarm problems. NFASS will always advise their customers to follow the procedure below before we visit the site to help identify the problem with their system. Many customers will contact their Fire Alarm maintenance company reporting false alarms in an area but unfortunately not knowing which device caused the activation. Service inspection undertaken by your Fire Alarm maintenance company.Minimum service time (this may be more frequent if specified by your risk assessment).If you have any doubts or worries about your system, contact your Fire Alarm maintenance company Ask your service company to train more staff during the service inspection.Ensure more than one person if familiar on the testing process.Make a note within your logbook the location of the call point you activated.Activate a call point (select a different call point each week).If your system is remotely monitored contact the monitoring company and place the system on test.Ensure the personal within the building are aware of the test (ideally test the system the same day & time each week).Our customers have free training on testing their system If there are any faults showing make a note then contact your Fire Alarm maintenance company.Ī different call point must be activated every week, with all the sounders checked and then recorded within a logbook.Įach fire alarm system is silenced then reset in a different way.Check to see if there is only a power light illuminated on the fire panel.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |